E-ISSN 2218-6050 | ISSN 2226-4485
 

Research Article 


Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus)

Isabela Canto, André Saldanha, Claudia Sayuri Saçaki, Fabiano Montiani-ferreira.


Abstract
Background:
The evaluation of aqueous tear film production in laboratory rodents is limited by the small palpebral fissure and globe size.

Aim:
This study aimed to compare aqueous tear film measurements obtained using different commercially available endodontic paper points (EPPs) in laboratory rats.

Methods:
Aqueous tear production was measured in 22 adult Rattus norvegicus using six size-30 EPP brands applied for 15 and 60 s. Brand comparisons were performed at each time point using the Friedman test with multiplicity-adjusted post hoc comparisons. Paired time comparisons (15 vs. 60 s) were analyzed using the Wilcoxon signed-rank test. The effect size was reported as r (Z/√N). The central 90% reference intervals (5th–95th percentile) were calculated for each brand and time point.

Results:
Brand-related differences were identified at 15 s (Friedman χ² = 38.56; p = 2.91 × 10⁻⁷) and 60 s (Friedman χ²= 31.79; p = 6.55 × 10⁻⁶). Measurements were higher at 60 s than at 15 s for all brands (all p ≤ 0.0057; all r ≥ 0.589). The values ranged from 4.39 ± 0.83 to 6.50 ± 1.46 mm at 15 s and from 6.73 ± 1.91 to 10.45 ± 3.00 mm at 60 s.

Conclusion:
EPPs are practical, simple, and minimally invasive tools for evaluating aqueous tear film in laboratory rats; however, to ensure reproducibility and accurate interpretation, brand-specific and time-specific reference intervals are recommended.

Key words: Aqueous tear production test; Endodontic paper points; Laboratory rats; Tear film; Veterinary ophthalmology.


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Isabela Canto
Articles by André Saldanha
Articles by Claudia Sayuri Saçaki
Articles by Fabiano Montiani-Ferreira
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Canto I, Saldanha A, Sacaki CS, Montiani-ferreira F. Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus). doi:10.5455/OVJ.2026.v16.i6.16


Web Style

Canto I, Saldanha A, Sacaki CS, Montiani-ferreira F. Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus). https://www.openveterinaryjournal.com/?mno=291595 [Access: June 05, 2026]. doi:10.5455/OVJ.2026.v16.i6.16


AMA (American Medical Association) Style

Canto I, Saldanha A, Sacaki CS, Montiani-ferreira F. Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus). doi:10.5455/OVJ.2026.v16.i6.16



Vancouver/ICMJE Style

Canto I, Saldanha A, Sacaki CS, Montiani-ferreira F. Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus). doi:10.5455/OVJ.2026.v16.i6.16



Harvard Style

Canto, I., Saldanha, . A., Sacaki, . C. S. & Montiani-ferreira, . F. (2026) Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus). doi:10.5455/OVJ.2026.v16.i6.16



Turabian Style

Canto, Isabela, André Saldanha, Claudia Sayuri Sacaki, and Fabiano Montiani-ferreira. 2026. Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus). doi:10.5455/OVJ.2026.v16.i6.16



Chicago Style

Canto, Isabela, André Saldanha, Claudia Sayuri Sacaki, and Fabiano Montiani-ferreira. "Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus)." doi:10.5455/OVJ.2026.v16.i6.16



MLA (The Modern Language Association) Style

Canto, Isabela, André Saldanha, Claudia Sayuri Sacaki, and Fabiano Montiani-ferreira. "Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus)." doi:10.5455/OVJ.2026.v16.i6.16



APA (American Psychological Association) Style

Canto, I., Saldanha, . A., Sacaki, . C. S. & Montiani-ferreira, . F. (2026) Comparison of aqueous tear film measurements obtained using different endodontic paper point brands in laboratory rats (Rattus norvegicus). doi:10.5455/OVJ.2026.v16.i6.16